NASA/IPAC EXTRAGALACTIC DATABASE
Date and Time of the Query: 2019-06-24 T08:16:00 PDT
Help | Comment | NED Home

Spectral Energy Distribution (SED) for SSTSL2 J004537.65-732312.6:

12 Data Points
 Click to zoom in at a position of interest (uses a separate window). 
Select zoom factor:  

                Postscript version of the SED plot






  New options   Format tabular data as:


Photometric Data --- Published and Homogenized [Frequency, Flux Density] Units

  Published UnitsHomogenized Units [Frequency, Flux Density]  
No.Observed PassbandMeasurementUncertaintyUnitsFreq (Hz)MeasurementUncertaintyUnitsModeAperture/QualifiersReference CodeNo.
1 3.6 microns (IRAC) 7.5513E+01 +/- 1.2944E+00 microJy 8.44E+13 7.55E-05 +/- 1.29E-06 Jy Broad-band 5.8" aperture 2013SSTSLC4.2....0C 1
2 3.6 microns (IRAC) 5.0366E+01 +/- 8.1483E-01 microJy 8.44E+13 5.04E-05 +/- 8.15E-07 Jy Broad-band 3.8" aperture 2013SSTSLC4.2....0C 2
3 3.6 microns (IRAC) 16.74 +/- 0.09 mag 8.44E+13 5.66E-05 +/- 4.69E-06 Jy Broad-band 2011AJ....142..102G 3
4 4.5 microns (IRAC) 3.4527E+01 +/- 1.0257E+00 microJy 6.67E+13 3.45E-05 +/- 1.03E-06 Jy Broad-band 3.8" aperture 2013SSTSLC4.2....0C 4
5 4.5 microns (IRAC) 4.4444E+01 +/- 1.6708E+00 microJy 6.67E+13 4.44E-05 +/- 1.67E-06 Jy Broad-band 5.8" aperture 2013SSTSLC4.2....0C 5
6 4.5 microns (IRAC) 16.70 +/- 0.09 mag 6.67E+13 3.75E-05 +/- 3.11E-06 Jy Broad-band 2011AJ....142..102G 6
7 5.8 microns (IRAC) ... <1.3805E+01 microJy 5.23E+13 < 1.38E-05 Jy Broad-band 5.8" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 7
8 5.8 microns (IRAC) ... <9.0878E+00 microJy 5.23E+13 < 9.09E-06 Jy Broad-band 3.8" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 8
9 8.0 microns (IRAC) ... <1.8645E+01 microJy 3.81E+13 < 1.86E-05 Jy Broad-band 5.8" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 9
10 8.0 microns (IRAC) ... <1.3482E+01 microJy 3.81E+13 < 1.35E-05 Jy Broad-band 3.8" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 10
11 24 microns (MIPS) ... <1.4082E+02 microJy 1.27E+13 < 1.41E-04 Jy Broad-band PSF fit; 3 sigma Upper Limit 2013SSTSLC4.2....0C 11
12 24 microns (MIPS) ... <1.4926E+02 microJy 1.27E+13 < 1.49E-04 Jy Broad-band 14.7" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 12


Detailed Information for Each Entry

 No. 1
Reference Code : 2013SSTSLC4.2....0C
Freq. targeted : 3.6 microns (IRAC)  
Measurement    :  7.5513E+01  microJy              = 7.55E-31 W m^-2^ Hz^-1^
Uncertainty    :  1.2944E+00  microJy              = 1.29E-32
Significance   : uncertainty
Freq or Vel.   : 3.55         microns      (OBS   )= 8.44E+13 Hz
Frequency mode : Broad-band measurement
Coord. targeted:
Spatial mode   : Flux in fixed aperture
Notes          : From new raw data
Qualifiers     : 5.8" aperture                           

No. 2 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 3.6 microns (IRAC) Measurement : 5.0366E+01 microJy = 5.04E-31 W m^-2^ Hz^-1^ Uncertainty : 8.1483E-01 microJy = 8.15E-33 Significance : uncertainty Freq or Vel. : 3.55 microns (OBS )= 8.44E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture
No. 3 Reference Code : 2011AJ....142..102G Freq. targeted : 3.6 microns (IRAC) Measurement : 16.74 mag = 5.66E-31 W m^-2^ Hz^-1^ Uncertainty : 0.09 mag = 4.69E-32 Significance : 1 sigma Freq or Vel. : 3.550 microns (OBS )= 8.44E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: 00 45 37.70 -73 23 12.9 (J2000) Spatial mode : Total flux Notes : From new raw data Qualifiers :
No. 4 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 4.5 microns (IRAC) Measurement : 3.4527E+01 microJy = 3.45E-31 W m^-2^ Hz^-1^ Uncertainty : 1.0257E+00 microJy = 1.03E-32 Significance : uncertainty Freq or Vel. : 4.493 microns (OBS )= 6.67E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture
No. 5 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 4.5 microns (IRAC) Measurement : 4.4444E+01 microJy = 4.44E-31 W m^-2^ Hz^-1^ Uncertainty : 1.6708E+00 microJy = 1.67E-32 Significance : uncertainty Freq or Vel. : 4.493 microns (OBS )= 6.67E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture
No. 6 Reference Code : 2011AJ....142..102G Freq. targeted : 4.5 microns (IRAC) Measurement : 16.70 mag = 3.75E-31 W m^-2^ Hz^-1^ Uncertainty : 0.09 mag = 3.11E-32 Significance : 1 sigma Freq or Vel. : 4.493 microns (OBS )= 6.67E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: 00 45 37.70 -73 23 12.9 (J2000) Spatial mode : Total flux Notes : From new raw data Qualifiers :
No. 7 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 5.8 microns (IRAC) Measurement : <1.3805E+01 microJy < 1.38E-31 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 5.731 microns (OBS )= 5.23E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture; 3 sigma Upper Limit
No. 8 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 5.8 microns (IRAC) Measurement : <9.0878E+00 microJy < 9.09E-32 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 5.731 microns (OBS )= 5.23E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture; 3 sigma Upper Limit
No. 9 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 8.0 microns (IRAC) Measurement : <1.8645E+01 microJy < 1.86E-31 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 7.872 microns (OBS )= 3.81E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture; 3 sigma Upper Limit
No. 10 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 8.0 microns (IRAC) Measurement : <1.3482E+01 microJy < 1.35E-31 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 7.872 microns (OBS )= 3.81E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture; 3 sigma Upper Limit
No. 11 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 24 microns (MIPS) Measurement : <1.4082E+02 microJy < 1.41E-30 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 23.68 microns (OBS )= 1.27E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Modelled datum Notes : From new raw data Qualifiers : PSF fit; 3 sigma Upper Limit
No. 12 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 24 microns (MIPS) Measurement : <1.4926E+02 microJy < 1.49E-30 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 23.68 microns (OBS )= 1.27E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 14.7" aperture; 3 sigma Upper Limit

Back to NED Home