NASA/IPAC EXTRAGALACTIC DATABASE
Date and Time of the Query: 2019-03-20 T20:58:42 PDT
Help | Comment | NED Home

Spectral Energy Distribution (SED) for SSTSL2 J012146.71-721831.1:

12 Data Points
 Click to zoom in at a position of interest (uses a separate window). 
Select zoom factor:  

                Postscript version of the SED plot






  New options   Format tabular data as:


Photometric Data --- Published and Homogenized [Frequency, Flux Density] Units

  Published UnitsHomogenized Units [Frequency, Flux Density]  
No.Observed PassbandMeasurementUncertaintyUnitsFreq (Hz)MeasurementUncertaintyUnitsModeAperture/QualifiersReference CodeNo.
1 3.6 microns (IRAC) 2.6690E+01 +/- 1.8721E+00 microJy 8.44E+13 2.67E-05 +/- 1.87E-06 Jy Broad-band 5.8" aperture 2013SSTSLC4.2....0C 1
2 3.6 microns (IRAC) 3.2288E+01 +/- 1.1645E+00 microJy 8.44E+13 3.23E-05 +/- 1.16E-06 Jy Broad-band 3.8" aperture 2013SSTSLC4.2....0C 2
3 3.6 microns (IRAC) 17.22 +/- 0.06 mag 8.44E+13 3.64E-05 +/- 2.01E-06 Jy Broad-band 2011AJ....142..102G 3
4 4.5 microns (IRAC) 2.5431E+01 +/- 2.5880E+00 microJy 6.67E+13 2.54E-05 +/- 2.59E-06 Jy Broad-band 5.8" aperture 2013SSTSLC4.2....0C 4
5 4.5 microns (IRAC) 2.4616E+01 +/- 1.6394E+00 microJy 6.67E+13 2.46E-05 +/- 1.64E-06 Jy Broad-band 3.8" aperture 2013SSTSLC4.2....0C 5
6 4.5 microns (IRAC) 16.81 +/- 0.13 mag 6.67E+13 3.39E-05 +/- 4.06E-06 Jy Broad-band 2011AJ....142..102G 6
7 5.8 microns (IRAC) ... <1.6457E+01 microJy 5.23E+13 < 1.65E-05 Jy Broad-band 3.8" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 7
8 5.8 microns (IRAC) ... <2.4688E+01 microJy 5.23E+13 < 2.47E-05 Jy Broad-band 5.8" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 8
9 8.0 microns (IRAC) ... <2.4637E+01 microJy 3.81E+13 < 2.46E-05 Jy Broad-band 3.8" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 9
10 8.0 microns (IRAC) ... <3.3933E+01 microJy 3.81E+13 < 3.39E-05 Jy Broad-band 5.8" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 10
11 24 microns (MIPS) ... <2.0524E+02 microJy 1.27E+13 < 2.05E-04 Jy Broad-band PSF fit; 3 sigma Upper Limit 2013SSTSLC4.2....0C 11
12 24 microns (MIPS) ... <2.4300E+02 microJy 1.27E+13 < 2.43E-04 Jy Broad-band 14.7" aperture; 3 sigma Upper Limit 2013SSTSLC4.2....0C 12


Detailed Information for Each Entry

 No. 1
Reference Code : 2013SSTSLC4.2....0C
Freq. targeted : 3.6 microns (IRAC)  
Measurement    :  2.6690E+01  microJy              = 2.67E-31 W m^-2^ Hz^-1^
Uncertainty    :  1.8721E+00  microJy              = 1.87E-32
Significance   : uncertainty
Freq or Vel.   : 3.55         microns      (OBS   )= 8.44E+13 Hz
Frequency mode : Broad-band measurement
Coord. targeted:
Spatial mode   : Flux in fixed aperture
Notes          : From new raw data
Qualifiers     : 5.8" aperture                           

No. 2 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 3.6 microns (IRAC) Measurement : 3.2288E+01 microJy = 3.23E-31 W m^-2^ Hz^-1^ Uncertainty : 1.1645E+00 microJy = 1.16E-32 Significance : uncertainty Freq or Vel. : 3.55 microns (OBS )= 8.44E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture
No. 3 Reference Code : 2011AJ....142..102G Freq. targeted : 3.6 microns (IRAC) Measurement : 17.22 mag = 3.64E-31 W m^-2^ Hz^-1^ Uncertainty : 0.06 mag = 2.01E-32 Significance : 1 sigma Freq or Vel. : 3.550 microns (OBS )= 8.44E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: 01 21 46.71 -72 18 31.2 (J2000) Spatial mode : Total flux Notes : From new raw data Qualifiers :
No. 4 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 4.5 microns (IRAC) Measurement : 2.5431E+01 microJy = 2.54E-31 W m^-2^ Hz^-1^ Uncertainty : 2.5880E+00 microJy = 2.59E-32 Significance : uncertainty Freq or Vel. : 4.493 microns (OBS )= 6.67E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture
No. 5 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 4.5 microns (IRAC) Measurement : 2.4616E+01 microJy = 2.46E-31 W m^-2^ Hz^-1^ Uncertainty : 1.6394E+00 microJy = 1.64E-32 Significance : uncertainty Freq or Vel. : 4.493 microns (OBS )= 6.67E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture
No. 6 Reference Code : 2011AJ....142..102G Freq. targeted : 4.5 microns (IRAC) Measurement : 16.81 mag = 3.39E-31 W m^-2^ Hz^-1^ Uncertainty : 0.13 mag = 4.06E-32 Significance : 1 sigma Freq or Vel. : 4.493 microns (OBS )= 6.67E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: 01 21 46.71 -72 18 31.2 (J2000) Spatial mode : Total flux Notes : From new raw data Qualifiers :
No. 7 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 5.8 microns (IRAC) Measurement : <1.6457E+01 microJy < 1.65E-31 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 5.731 microns (OBS )= 5.23E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture; 3 sigma Upper Limit
No. 8 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 5.8 microns (IRAC) Measurement : <2.4688E+01 microJy < 2.47E-31 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 5.731 microns (OBS )= 5.23E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture; 3 sigma Upper Limit
No. 9 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 8.0 microns (IRAC) Measurement : <2.4637E+01 microJy < 2.46E-31 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 7.872 microns (OBS )= 3.81E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture; 3 sigma Upper Limit
No. 10 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 8.0 microns (IRAC) Measurement : <3.3933E+01 microJy < 3.39E-31 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 7.872 microns (OBS )= 3.81E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture; 3 sigma Upper Limit
No. 11 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 24 microns (MIPS) Measurement : <2.0524E+02 microJy < 2.05E-30 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 23.68 microns (OBS )= 1.27E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Modelled datum Notes : From new raw data Qualifiers : PSF fit; 3 sigma Upper Limit
No. 12 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 24 microns (MIPS) Measurement : <2.4300E+02 microJy < 2.43E-30 W m^-2^ Hz^-1^ Uncertainty : Significance : 3 sigma Freq or Vel. : 23.68 microns (OBS )= 1.27E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 14.7" aperture; 3 sigma Upper Limit

Back to NED Home