NASA/IPAC EXTRAGALACTIC DATABASE
Date and Time of the Query: 2022-01-23 T05:21:12 PST
Help | Comment | NED Home

Spectral Energy Distribution (SED) for SSTSL2 J073632.20+653031.5:

31 Data Points
 Click to zoom in at a position of interest (uses a separate window). 
Select zoom factor:  

                Postscript version of the SED plot






  New options   Format tabular data as:


Photometric Data --- Published and Homogenized [Frequency, Flux Density] Units

  Published UnitsHomogenized Units [Frequency, Flux Density]  
No.Observed PassbandMeasurementUncertaintyUnitsFreq (Hz)MeasurementUncertaintyUnitsModeAperture/QualifiersReference CodeNo.
1 0.35-8 keV (Chandra) 13.6E-15 ... erg/s/cm^2^ 1.01E+18 1.35E-09 ... Jy Broad-band Unabsorbed flux 2015AJ....150...94B 1
2 0.3-8 keV (Chandra) 2.00E-14 ... erg/s/cm^2^ 1.00E+18 2.00E-09 ... Jy Broad-band 2011ApJS..192...10L 2
3 0.3-8 keV (Chandra) 3.21E-14 ... erg/cm^2^/s 1.00E+18 3.21E-09 ... Jy Broad-band Average flux 2016ApJS..224...40W 3
4 0.5-7 keV Chandra ... <1.0625E-15 erg/cm^2/s 5.56E+17 < 1.91E-10 Jy Broad-band flux_aper 2020CSC...C2..0000: 4
5 0.5-7 keV Chandra 6.9129E-15 +/- 1.1306E-15 erg/cm^2/s 5.56E+17 1.24E-09 +/- 2.03E-10 Jy Broad-band flux_aper_avg 2020CSC...C2..0000: 5
6 0.5-7 keV Chandra 2.3719E-15 +/- 1.0232E-15 erg/cm^2/s 5.56E+17 4.27E-10 +/- 1.84E-10 Jy Broad-band flux_aper90 2020CSC...C2..0000: 6
7 0.5-7 keV Chandra 7.0344E-15 +/- 1.1258E-15 erg/cm^2/s 5.56E+17 1.26E-09 +/- 2.02E-10 Jy Broad-band flux_aper90_avg 2020CSC...C2..0000: 7
8 1.2-2 keV Chandra ... <2.3832E-16 erg/cm^2/s 3.77E+17 < 6.32E-11 Jy Broad-band flux_aper 2020CSC...C2..0000: 8
9 1.2-2 keV Chandra 6.8448E-16 +/- 2.1615E-16 erg/cm^2/s 3.77E+17 1.81E-10 +/- 5.73E-11 Jy Broad-band flux_aper_avg 2020CSC...C2..0000: 9
10 1.2-2 keV Chandra 1.8710E-16 +/- 1.8710E-16 erg/cm^2/s 3.77E+17 4.96E-11 +/- 4.96E-11 Jy Broad-band flux_aper90 2020CSC...C2..0000: 10
11 1.2-2 keV Chandra 7.8420E-16 +/- 2.3925E-16 erg/cm^2/s 3.77E+17 2.08E-10 +/- 6.34E-11 Jy Broad-band flux_aper90_avg 2020CSC...C2..0000: 11
12 0.1-10 keV Chandra ... <1.6733E-14 erg/cm^2/s 3.63E+17 < 4.61E-09 Jy Broad-band flux_aper_avg 2020CSC...C2..0000: 12
13 0.1-10 keV Chandra ... <1.6733E-14 erg/cm^2/s 3.63E+17 < 4.61E-09 Jy Broad-band flux_aper90_avg 2020CSC...C2..0000: 13
14 0.5-1.2 keV Chandra 6.7358E-16 +/- 2.5797E-16 erg/cm^2/s 2.22E+17 3.03E-10 +/- 1.16E-10 Jy Broad-band flux_aper 2020CSC...C2..0000: 14
15 0.5-1.2 keV Chandra 1.4900E-15 +/- 2.8723E-16 erg/cm^2/s 2.22E+17 6.70E-10 +/- 1.29E-10 Jy Broad-band flux_aper_avg 2020CSC...C2..0000: 15
16 0.5-1.2 keV Chandra 6.6496E-16 +/- 2.4936E-16 erg/cm^2/s 2.22E+17 2.99E-10 +/- 1.12E-10 Jy Broad-band flux_aper90 2020CSC...C2..0000: 16
17 0.5-1.2 keV Chandra 1.5290E-15 +/- 2.9834E-16 erg/cm^2/s 2.22E+17 6.87E-10 +/- 1.34E-10 Jy Broad-band flux_aper90_avg 2020CSC...C2..0000: 17
18 0.2-0.5 keV Chandra 4.8043E-15 +/- 1.2678E-15 erg/cm^2/s 9.67E+16 4.97E-09 +/- 1.31E-09 Jy Broad-band flux_aper_avg 2020CSC...C2..0000: 18
19 0.2-0.5 keV Chandra ... <1.2667E-15 erg/cm^2/s 9.67E+16 < 1.31E-09 Jy Broad-band flux_aper 2020CSC...C2..0000: 19
20 0.2-0.5 keV Chandra 2.5371E-15 +/- 1.4232E-15 erg/cm^2/s 9.67E+16 2.62E-09 +/- 1.47E-09 Jy Broad-band flux_aper90 2020CSC...C2..0000: 20
21 0.2-0.5 keV Chandra 5.7751E-15 +/- 1.3327E-15 erg/cm^2/s 9.67E+16 5.97E-09 +/- 1.38E-09 Jy Broad-band flux_aper90_avg 2020CSC...C2..0000: 21
22 3.6 microns (IRAC) 6.4766E+01 +/- 1.6912E-01 microJy 8.44E+13 6.48E-05 +/- 1.69E-07 Jy Broad-band 3.8" aperture 2013SSTSLC4.2....0C 22
23 3.6 microns (IRAC) 7.0514E+01 +/- 1.7385E-01 microJy 8.44E+13 7.05E-05 +/- 1.74E-07 Jy Broad-band 5.8" aperture 2013SSTSLC4.2....0C 23
24 4.5 microns (IRAC) 6.5606E+01 +/- 5.9964E-01 microJy 6.67E+13 6.56E-05 +/- 6.00E-07 Jy Broad-band 5.8" aperture 2013SSTSLC4.2....0C 24
25 4.5 microns (IRAC) 6.2419E+01 +/- 3.8218E-01 microJy 6.67E+13 6.24E-05 +/- 3.82E-07 Jy Broad-band 3.8" aperture 2013SSTSLC4.2....0C 25
26 5.8 microns (IRAC) 5.9537E+01 +/- 5.9219E-01 microJy 5.23E+13 5.95E-05 +/- 5.92E-07 Jy Broad-band 3.8" aperture 2013SSTSLC4.2....0C 26
27 5.8 microns (IRAC) 6.4016E+01 +/- 7.6137E-01 microJy 5.23E+13 6.40E-05 +/- 7.61E-07 Jy Broad-band 5.8" aperture 2013SSTSLC4.2....0C 27
28 8.0 microns (IRAC) 7.7644E+01 +/- 2.7078E+00 microJy 3.81E+13 7.76E-05 +/- 2.71E-06 Jy Broad-band 3.8" aperture 2013SSTSLC4.2....0C 28
29 8.0 microns (IRAC) 5.9648E+01 +/- 3.6502E+00 microJy 3.81E+13 5.96E-05 +/- 3.65E-06 Jy Broad-band 5.8" aperture 2013SSTSLC4.2....0C 29
30 24 microns (MIPS) 2.6509E+02 +/- 2.0103E+01 microJy 1.27E+13 2.65E-04 +/- 2.01E-05 Jy Broad-band 14.7" aperture 2013SSTSLC4.2....0C 30
31 24 microns (MIPS) 2.5483E+02 +/- 2.1236E+01 microJy 1.27E+13 2.55E-04 +/- 2.12E-05 Jy Broad-band PSF fit 2013SSTSLC4.2....0C 31


Detailed Information for Each Entry

 No. 1
Reference Code : 2015AJ....150...94B
Freq. targeted : 0.35-8 keV (Chandra)
Measurement    :  13.6E-15    erg/s/cm^2^          = 1.36E-17 W m^-2^
Uncertainty    :              erg/s/cm^2^          = 0.00E+00
Significance   : no uncertainty reported
Freq or Vel.   :       4.17   keV          (OBS   )= 1.01E+18 Hz
Frequency mode : Broad-band measurement
Coord. targeted: 114.134260      65.508730 (J2000)
Spatial mode   : Modelled datum
Notes          : From reprocessed raw data; NED frequency assigned to
                 mid-point of band in keV
Qualifiers     : Unabsorbed flux                         

No. 2 Reference Code : 2011ApJS..192...10L Freq. targeted : 0.3-8 keV (Chandra) Measurement : 2.00E-14 erg/s/cm^2^ = 2.00E-17 W m^-2^ Uncertainty : erg/s/cm^2^ = 0.00E+00 Significance : no uncertainty reported Freq or Vel. : 4.15 keV (OBS )= 1.00E+18 Hz Frequency mode : Broad-band measurement Coord. targeted: 07 36 32.201 +65 30 31.39 (J2000) Spatial mode : Flux integrated from map Notes : From reprocessed raw data; NED frequency assigned to mid-point of band in keV Qualifiers :
No. 3 Reference Code : 2016ApJS..224...40W Freq. targeted : 0.3-8 keV (Chandra) Measurement : 3.21E-14 erg/cm^2^/s = 3.21E-17 W m^-2^ Uncertainty : erg/cm^2^/s = 0.00E+00 Significance : no uncertainty reported Freq or Vel. : 4.15 keV (OBS )= 1.00E+18 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux integrated from map Notes : From reprocessed raw data; NED frequency assigned to mid-point of band in keV Qualifiers : Average flux
No. 4 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.5-7 keV Chandra Measurement : <1.0625E-15 erg/cm^2/s < 1.06E-18 W m^-2^ Uncertainty : Significance : 68% confidence Freq or Vel. : 2.3 keV (OBS )= 5.56E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper
No. 5 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.5-7 keV Chandra Measurement : 6.9129E-15 erg/cm^2/s = 6.91E-18 W m^-2^ Uncertainty : 1.1306E-15 erg/cm^2/s = 1.13E-18 Significance : 68% confidence Freq or Vel. : 2.3 keV (OBS )= 5.56E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper_avg
No. 6 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.5-7 keV Chandra Measurement : 2.3719E-15 erg/cm^2/s = 2.37E-18 W m^-2^ Uncertainty : 1.0232E-15 erg/cm^2/s = 1.02E-18 Significance : 68% confidence Freq or Vel. : 2.3 keV (OBS )= 5.56E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90
No. 7 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.5-7 keV Chandra Measurement : 7.0344E-15 erg/cm^2/s = 7.03E-18 W m^-2^ Uncertainty : 1.1258E-15 erg/cm^2/s = 1.13E-18 Significance : 68% confidence Freq or Vel. : 2.3 keV (OBS )= 5.56E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90_avg
No. 8 Reference Code : 2020CSC...C2..0000: Freq. targeted : 1.2-2 keV Chandra Measurement : <2.3832E-16 erg/cm^2/s < 2.38E-19 W m^-2^ Uncertainty : Significance : 68% confidence Freq or Vel. : 1.56 keV (OBS )= 3.77E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper
No. 9 Reference Code : 2020CSC...C2..0000: Freq. targeted : 1.2-2 keV Chandra Measurement : 6.8448E-16 erg/cm^2/s = 6.84E-19 W m^-2^ Uncertainty : 2.1615E-16 erg/cm^2/s = 2.16E-19 Significance : 68% confidence Freq or Vel. : 1.56 keV (OBS )= 3.77E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper_avg
No. 10 Reference Code : 2020CSC...C2..0000: Freq. targeted : 1.2-2 keV Chandra Measurement : 1.8710E-16 erg/cm^2/s = 1.87E-19 W m^-2^ Uncertainty : 1.8710E-16 erg/cm^2/s = 1.87E-19 Significance : 68% confidence Freq or Vel. : 1.56 keV (OBS )= 3.77E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90
No. 11 Reference Code : 2020CSC...C2..0000: Freq. targeted : 1.2-2 keV Chandra Measurement : 7.8420E-16 erg/cm^2/s = 7.84E-19 W m^-2^ Uncertainty : 2.3925E-16 erg/cm^2/s = 2.39E-19 Significance : 68% confidence Freq or Vel. : 1.56 keV (OBS )= 3.77E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90_avg
No. 12 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.1-10 keV Chandra Measurement : <1.6733E-14 erg/cm^2/s < 1.67E-17 W m^-2^ Uncertainty : Significance : 68% confidence Freq or Vel. : 1.5 keV (OBS )= 3.63E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper_avg
No. 13 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.1-10 keV Chandra Measurement : <1.6733E-14 erg/cm^2/s < 1.67E-17 W m^-2^ Uncertainty : Significance : 68% confidence Freq or Vel. : 1.5 keV (OBS )= 3.63E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90_avg
No. 14 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.5-1.2 keV Chandra Measurement : 6.7358E-16 erg/cm^2/s = 6.74E-19 W m^-2^ Uncertainty : 2.5797E-16 erg/cm^2/s = 2.58E-19 Significance : 68% confidence Freq or Vel. : 0.92 keV (OBS )= 2.22E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper
No. 15 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.5-1.2 keV Chandra Measurement : 1.4900E-15 erg/cm^2/s = 1.49E-18 W m^-2^ Uncertainty : 2.8723E-16 erg/cm^2/s = 2.87E-19 Significance : 68% confidence Freq or Vel. : 0.92 keV (OBS )= 2.22E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper_avg
No. 16 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.5-1.2 keV Chandra Measurement : 6.6496E-16 erg/cm^2/s = 6.65E-19 W m^-2^ Uncertainty : 2.4936E-16 erg/cm^2/s = 2.49E-19 Significance : 68% confidence Freq or Vel. : 0.92 keV (OBS )= 2.22E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90
No. 17 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.5-1.2 keV Chandra Measurement : 1.5290E-15 erg/cm^2/s = 1.53E-18 W m^-2^ Uncertainty : 2.9834E-16 erg/cm^2/s = 2.98E-19 Significance : 68% confidence Freq or Vel. : 0.92 keV (OBS )= 2.22E+17 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90_avg
No. 18 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.2-0.5 keV Chandra Measurement : 4.8043E-15 erg/cm^2/s = 4.80E-18 W m^-2^ Uncertainty : 1.2678E-15 erg/cm^2/s = 1.27E-18 Significance : 68% confidence Freq or Vel. : 0.4 keV (OBS )= 9.67E+16 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper_avg
No. 19 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.2-0.5 keV Chandra Measurement : <1.2667E-15 erg/cm^2/s < 1.27E-18 W m^-2^ Uncertainty : Significance : 68% confidence Freq or Vel. : 0.4 keV (OBS )= 9.67E+16 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : flux_aper
No. 20 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.2-0.5 keV Chandra Measurement : 2.5371E-15 erg/cm^2/s = 2.54E-18 W m^-2^ Uncertainty : 1.4232E-15 erg/cm^2/s = 1.42E-18 Significance : 68% confidence Freq or Vel. : 0.4 keV (OBS )= 9.67E+16 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90
No. 21 Reference Code : 2020CSC...C2..0000: Freq. targeted : 0.2-0.5 keV Chandra Measurement : 5.7751E-15 erg/cm^2/s = 5.78E-18 W m^-2^ Uncertainty : 1.3327E-15 erg/cm^2/s = 1.33E-18 Significance : 68% confidence Freq or Vel. : 0.4 keV (OBS )= 9.67E+16 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : From fitting to map Notes : From new raw data Qualifiers : flux_aper90_avg
No. 22 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 3.6 microns (IRAC) Measurement : 6.4766E+01 microJy = 6.48E-31 W m^-2^ Hz^-1^ Uncertainty : 1.6912E-01 microJy = 1.69E-33 Significance : uncertainty Freq or Vel. : 3.55 microns (OBS )= 8.44E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture
No. 23 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 3.6 microns (IRAC) Measurement : 7.0514E+01 microJy = 7.05E-31 W m^-2^ Hz^-1^ Uncertainty : 1.7385E-01 microJy = 1.74E-33 Significance : uncertainty Freq or Vel. : 3.55 microns (OBS )= 8.44E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture
No. 24 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 4.5 microns (IRAC) Measurement : 6.5606E+01 microJy = 6.56E-31 W m^-2^ Hz^-1^ Uncertainty : 5.9964E-01 microJy = 6.00E-33 Significance : uncertainty Freq or Vel. : 4.493 microns (OBS )= 6.67E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture
No. 25 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 4.5 microns (IRAC) Measurement : 6.2419E+01 microJy = 6.24E-31 W m^-2^ Hz^-1^ Uncertainty : 3.8218E-01 microJy = 3.82E-33 Significance : uncertainty Freq or Vel. : 4.493 microns (OBS )= 6.67E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture
No. 26 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 5.8 microns (IRAC) Measurement : 5.9537E+01 microJy = 5.95E-31 W m^-2^ Hz^-1^ Uncertainty : 5.9219E-01 microJy = 5.92E-33 Significance : uncertainty Freq or Vel. : 5.731 microns (OBS )= 5.23E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture
No. 27 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 5.8 microns (IRAC) Measurement : 6.4016E+01 microJy = 6.40E-31 W m^-2^ Hz^-1^ Uncertainty : 7.6137E-01 microJy = 7.61E-33 Significance : uncertainty Freq or Vel. : 5.731 microns (OBS )= 5.23E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture
No. 28 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 8.0 microns (IRAC) Measurement : 7.7644E+01 microJy = 7.76E-31 W m^-2^ Hz^-1^ Uncertainty : 2.7078E+00 microJy = 2.71E-32 Significance : uncertainty Freq or Vel. : 7.872 microns (OBS )= 3.81E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 3.8" aperture
No. 29 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 8.0 microns (IRAC) Measurement : 5.9648E+01 microJy = 5.96E-31 W m^-2^ Hz^-1^ Uncertainty : 3.6502E+00 microJy = 3.65E-32 Significance : uncertainty Freq or Vel. : 7.872 microns (OBS )= 3.81E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 5.8" aperture
No. 30 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 24 microns (MIPS) Measurement : 2.6509E+02 microJy = 2.65E-30 W m^-2^ Hz^-1^ Uncertainty : 2.0103E+01 microJy = 2.01E-31 Significance : uncertainty Freq or Vel. : 23.68 microns (OBS )= 1.27E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Flux in fixed aperture Notes : From new raw data Qualifiers : 14.7" aperture
No. 31 Reference Code : 2013SSTSLC4.2....0C Freq. targeted : 24 microns (MIPS) Measurement : 2.5483E+02 microJy = 2.55E-30 W m^-2^ Hz^-1^ Uncertainty : 2.1236E+01 microJy = 2.12E-31 Significance : uncertainty Freq or Vel. : 23.68 microns (OBS )= 1.27E+13 Hz Frequency mode : Broad-band measurement Coord. targeted: Spatial mode : Modelled datum Notes : From new raw data Qualifiers : PSF fit

Back to NED Home